Venttk commercial industrial duct roof air conditioning unit for T3 conditions

Rooftop Air Conditioning Unit1) BRIEF INTRODUCTION AND FEATURESRooftop air-conditioning unit is DX air-cooled type, combined of the refrigeration system, control systems and different air handling sections, achieving cooling, heating, dehumidification, humidification, air purification, sterilization and other func

Featured Products

Rooftop Air Conditioning Unit

1) BRIEF INTRODUCTION AND FEATURES
Rooftop air-conditioning unit is DX air-cooled type, combined of the refrigeration system, control systems and different air handling sections, achieving cooling, heating, dehumidification, humidification, air purification, sterilization and other functions.Complete with a wide cooling capacity range, no need cooling water system, omit the dedicated room and complex cooling towers, water pumps and the corresponding pipelines, control device. Unit usually mounted on the roof or other outdoor location, don't need dedicated room, which greatly save the cost of civil work. Besides, It's easy to install--- only to connect the duct then power on to run, which also save the cost of maintenance.
Venttk Commercial Industrial Air Duct Rooftop Packaged Air Conditioner Unit Use for T3 Condition

2) Main Unit Descriptions
1) Efficient and Energy-saving.
Each outdoor unit incorporates high efficiency scroll compressors.
Coils use high efficient inner screw copper tube for better heat transfer.
Fresh air non energy dissipating cooling in transient season, can adjust air volume what the fresh air system
required.
OEM energy recovery device.
2) Durable( corrosion and rust protection).
Our packaged systems are built tough towithstand all weathers.
Their durable construction ensures a long life and excellent return on your investment.
The outdoor air coils' aluminum fins could be epoxy coated for extra protection in corrosive environments, e.g. salt
laden sea air.
Blue-fin type coils, epoxy resin fin coils as well as the copper fin coils are also available as an option.
Cabinets are constructed from high grade steel - polyester powder coated for all weather protection.
External fasteners are stainless steel or galvanized type.
Corrosion resistant drain trays are also included.
Designed to evacuate rain water and condensed water easily from the unit.
The opening for the connection side ducts are protected
so that water will not splash on the joint between the duct and unit panel.

3)Safety.
Complete with various protecting function.
Pass kinds of safety tests.
4) Easy service.
Quick release fasteners are provided on electrical and compressor panel.
The units are equipments with access door to all components that may require maintenance or service.
The liquid sight glasses are visible and easy to find.
Access to the control circuit and compressor section is independent of the cooling or heating operation of the unit.
5) Options.
Electric heater, hot-water heating, steam-heating unit.
Manul/electric fresh air damper, plug fan, dedicated exhaust fan air filter dirty alarm device.
Energy recovery device.


Venttk Commercial Industrial Air Duct Rooftop Packaged Air Conditioner Unit Use for T3 Condition

Standard heat pump type rooftop air conditioner
Spec table 1
ModelWRF12ZAWRF 15ZAWRF18ZAWRF24ZAWRF30ZAWRF 35ZA
WF12ZAWF 15ZAWF18ZAWF24ZAWF30ZAWF 35ZA
Cooling capacitykW1215.217.52430.335.6
Heating capacitykW13.216.618.426.533.337.7
Energy regulation
 
%0,100%0,50,100%
Power380V / 3Ph / 50HZA
Cooling input capacitykW4.15.35.58.811.312.3
Heating input capacitykW3.84.85.18.210.411.3
Start currentA486263637476
Cooling running currentA7.49.710.216.121.223.3
Heating running currentA6.99.29.715.120.122.2
Throttling method
 
Thermal expansion valve
 
Cooling system111122
RefrigerantR410A
CompressorCompressor typeHermetic scroll compressor
 
Qty111122
Condensation side
 
 
CondenserTypeCopper tube and aluminum fin
Qty111111
Drive typeDirect drive
Motor powerkW0.250.370.370.550.750.75
Air volumem3 /h 46007800780090001260012600
Evaporation side
 
 
EvapotatorTypeCopper tube and aluminum fin
Qty111111
Motor powerkW0.320.370.451.11.52.2
Air volumem3 /h210026003400410052006300
Drive typeDirect drivePulley
Static pressure(Pa)100100100200200250
FilterAluminum filter G3
Noise dB(A)676768717272
Refrigerant filling volume(kg)3.13.14.32x3.12x3.12x4.3
External dimensionLmm141014101410197819781978
Wmm110011001100117511751175
Hmm109510951095109510951095
Weightkg240260290420480500

Note: 1. Nominal cooling capacity is under nominal air volume, indoor DB/WB temperature is 27ºC/19ºC and outdoor DB/WB temperature is 35ºC/24ºC condition;
2. Nominal heating capacity is under nominal air volume, indoor DB/WB temperature is 20ºC/15ºC and outdoor DB/WB temperature is 7ºC/6ºC condition;


Spec table 2
ModelWRF45ZAWRF50ZAWRF 60ZAWRF72ZAWRF 90ZAWRF105ZA
WF 45ZAWF 50ZAWF 60ZAWF 72ZAWF90ZAWF 105ZA
Cooling capacitykW44.550607090105
Heating capacitykW48.754.36475.496.2113.2
Energy regulation
 
%0,33,66,1000,30,70,1000,50,1000,50,1000,33,66,1000,33,66,100
Power  380V / 3Ph / 50HZA
Cooling input capacitykW1719.522.826.732.939.7
Heating input capacitykW15.6182124.830.436.7
Start currentA168186175199197266
Cooling running currentA31.735.639.948.36170.6
Heating running currentA29.933.537.545.457.366.3
Throttling method
 
                                   Thermal expansion valve
 
Cooling system1 
RefrigerantR410A
CompressorCompressor typeHermetic scroll compressor
   
Qty222233
Condensation side
 
CondenserTypeCopper pipe copper fin
FanQty111122
Drive typeDirect drive
Motor powerkW1.11.51.52.22X1.12X1.5
Air volumem3 /h165002100021000270003300042000
   a2.653.823.825.492.653.82
   kw1.142.022.022.8751.142.02
Evaporation side
 
EvaporatorTypeEvaporator
 Qty 11111
Motor power 33445.55.5
Air volume 7600850010900125001600019500
Drive type 
Static pressure(Pa)250250300300300300
FilterAluminum filter G3
Noise dB(A)737373757475
Refrigerant filling volume(kg)4.3+4.3+8.52x7.52x8.53x7.53x8.5
External dimensionLmm226822682298229828782878
Wmm144014401650165021402140
Hmm116711671400140019641964
Weight 75077088096011601350
Note: 1. Nominal cooling capacity is under nominal air volume, indoor DB/WB temperature is 27ºC/19ºC and outdoor DB/WB temperature is 35ºC/24ºC condition;
2. Nominal heating capacity is under nominal air volume, indoor DB/WB temperature is 20ºC/15ºC and outdoor DB/WB temperature is 7ºC/6ºC condition;

Spec table 3
ModelWRF120ZAWRF140ZAWRF150ZAWRF180ZAWRF210ZAWRF300ZA
WF120ZAWF140ZAWF150ZAWF180ZAWF210ZAWF300ZA
Cooling capacitykW120140149180210298
Heating capacitykW128.3150159.2192.5226318
Energy regulation
 
%0,25,50,75,1000,50,1000,16.6,33.3,50,66.4,83,1000,25,50,75,100
Power  380V / 3Ph / 50HZA
Cooling input capacitykW45.155.755.169.983106.7
Heating input capacitykW41.751.851.564.877100
Start currentA218252323232301415
Cooling running currentA82.4101.4100.2130.9151192.3
Heating running currentA77.495.795.1123.5142.3184.3
Throttling method
 
        Thermal expansion valve
Cooling system442664
RefrigerantR410A
CompressorCompressor typeHermetic scroll compressor
380V / 3Ph / 50HZA
Qty442664
Condensation side
 
CondenserTypeCopper pipe copper fin
FanQty222444
Drive typeDirect drive
Motor powerkW2X1.52x2.22x2.24X1.14X1.54x2.2
Air volumem3 /h4200054000540006600084000108000
Evaporation side
 
 
EvaporatorTypeCopper pipe copper fin
 Qty111111
Motor powerkW7.51111151518.5
Air volumem3 /h210002500026000320003800054000
Drive typePulley
Static pressure(Pa)400400 500500500
FilterAluminum filter  G3
Noise dB(A)757979808082
Refrigerant filling volume(kg)4x7.54x8.52x176x7.56x8.5   4x14
External dimensionLmm362636263626469046905660
Wmm220022002200233023302330
Hmm204720472047205524272055
Weightkg171018201850218024302860
Note: 1. Nominal cooling capacity is under nominal air volume, indoor DB/WB temperature is 27ºC/19ºC and outdoor DB/WB temperature is 35ºC/24ºC condition;
2. Nominal heating capacity is under nominal air volume, indoor DB/WB temperature is 20ºC/15ºC and outdoor DB/WB temperature is 7ºC/6ºC condition;








 

Contact us